The screen will go back to normal reading mode within a. How to calibrate the msa altair 4 gas detector ideal. Multi gas detector msa the safety company united states. Msa altair 4x gas detector 4 gas monitor that simultaneously measures up to 4 gases. See msa link documentation for detailed instructions. You have officially calibrated your msa altair 4 or msa altair 4x gas monitor. How do i manually calibrate the msa altair 4x multi gas detector. How do i manually calibrate the msa altair 4x multi gas. Msa s network of distributors can help find the right product for you. Msa combustible gases, oxygen and carbon monoxide altair r 4x gas monitor with rechargeable battery and motion. Page 36 ensure that the calibration cap is properly seated. May 31, 2011 once the calibration procedure is completed, turn your gas off and remove the calibration adapter from the msa altair 4 or msa altair 4x. This supplier, prosafety, inc, did not ship the product as described. Msa 10107602 altair 4x gas detector, lel, o2, co, h2s, charcoal housing with msa xcell sensor technology msas altair 4x mining multigas detector is driven by xcell sensor technology with asic design.
Methaneoptimized catalytic bead sensor provides increased stability over time. The warranties made by msa the safety company with respect to the product are voided if the product is not used and maintained in accordance wit h the instructions in this manual. Cylinder of calibration gas blended to match levels for the msa altair 4x gas detector. The msa altair 4x is a beautifully designed and very functional confined space gas monitor.
Correct use the altair 5 multigas detector is for use by trained and qualified personnel. Altair 5x gas detector natural gas and pid msa safety. The selection and use of the product are the exclusive responsibility of the individual operator. Altair 4xr gas multi gas detector msa safety united. Do this by pressing and holding right beeps at you and the screen asks you to zero the. Altair 4x msha multigas detector technical faq datasheet. Measuring instruments msa altair 4x operating manual. Msa altair 4x gas monitor rental jendco safety supply. This declaration is based on the ectype examination certificate ftzu 07 atex 0169 x in accordance with annex iii of the atex directive 949ec. Altair pump probe in portable gas detection msa safety. Detecting specific toxic gases for which a sensor is installed it is imperative that this operating manual be r ead and observed when using the device.
Msa altair 4x multigas gas monitor detector with universal pump probe. Correct use the altair is a portable instrument for monitoring toxic gases and oxygen deficiency or excess in the workplace. Turn the msa altair 4 and msa altair 4x on in normal reading mode. Please protect yourself and others by following them. Product liability claims, warranties also as guarantees made by msa with respect. Msa altair 5x gas detector measures up to 6 gases including natural gas. Msa altair 4 gas monitor calibration guide by ideal. A short tutorial on how to perform a manual calibration of your msa altair 4x personal gas monitor for confined space entry. D12059 berlin we declare that the msa altair 4x complies with the provisions of the council directive 949ec atex. Altair 4xr gas multi gas detector msa safety united kingdom. Once the calibration procedure is completed, turn your gas off and remove the calibration adapter from the msa altair 4 or msa altair 4x.
Altair 4x mining multigas detector in portable gas detection. Msa altair 4x gas detector msa the safety company peru. Under normal circumstances msa recommends calibration at least every six months, however, many european. Simplicity counts with the msa galaxy gx2 automated test system for advanced safety management and effortless operation. Mar 25, 2019 get started with altair connect to see realtime gas readings, quickly check instrument status and remotely monitor your gas detectors through safety io grid. Connect one end of the tubing to the calibration cap. Msa instrument safety altair 5 operating manual 5 1. In particular, the safety instructions, as well as the information for the use and operation of the device, must be carefully read and observed. Altair 4x msha multigas detector instruction manual.
How to setchange date and time on msa altair 4 4x duration. Assess potential worker exposure to combustible and toxic gases and vapors as well as low level of oxygen. Pass button press span calibration measurement fig. Altair family gas detectors msa the safety company. Spare filters, sensors gasket, socket head cap screws 4x. Msa altair 4x manual calibration presented by gilson. Altair 4x msha multigas detector instruction manual in north america, to contact your nearest stocking location, dial tollfree 1800msa2222 to contact msa international, dial 7247768626 or 1800msa7777. Msa altair 4x gas detector 4 gas monitor perfect for various industries. Once the msa altair 4 and msa altair 4x is in normal reading mode, you need to send it into calibration mode. Altair 4xr gas multi gas detector msa safety united states. The screen will go back to normal reading mode within a few seconds. We encourage our customers to write or call regarding this. If you wish to have your msa altair 4x or 4xr calibrated by our service team then complete the rma form on our website. Altair 4x multigas detector instruction manual msa gas.
Altair 4xr multi gas detector is the toughest 4 gas monitor with a 4year warranty. This rugged unit is designed to withstand a drop of up to 20 ft 6m and uses less than half as much calibration gas. To contact msa international, dial 7247768626 or 1800msa7777. Once the msa altair 4 and msa altair 4x is in normal. Now available with a pid detector for voc detection. Altair 4xr gas multi gas detector msa safety canada. The altair 4x 10107602 multigas detector surpasses industry standards in several crucial areas. It is used exclusively for monitoring and not for measuring gas concentrations in the ambient air. Msa instrument safety altair 4 operating manual 5 1 instrument safety 1. See current readings, alarm status, calibration status, send. Msa safety regulations altair operating manual 5 1. Msa safety 100879 charger for altair 4x and 5x multigas detector.
Msa altair 4x gas detector msa safety united kingdom. Altair 4x msha multigas detector instruction manual instrumart. Please like the video if you found this to be helpful for more. Recheck calibration if device is subjected to physical shock. Hold the up arrow down for 3 seconds until zero cal shows, ensuring youre in a freshair environment. The galaxy gx2 test stand is not a csa certified calibration method. Combustible gas cross reference factors for altair 4x generalpurpose calibration using calibration cylinder pn 10045035 set to 58% lel. Msa altair 4x wall charger, power supply, 100879, with multi outlet adapters. Technology offers durability and performance for mining applications. It is designed to be used when performing a hazard assessment to. Before each use, check the function and calibration of the device. Its fouryear sensor life is 60% longer than the industry average, while its 24hour run time exceeds the industry average by 71%.
Combined with a safety io grid subscription, remotely monitor a fleet of altair 4xr or 5x gas detectors in real time. Jan 18, 2018 if you wish to have your msa altair 4x or 4xr calibrated by our service team then complete the rma form on our website. The galaxy gx2 automated test system provides simple, intelligent testing and calibration of msa altair and altair pro singlegas detectors and altair 4x and altair 5x multigas detectors. Msa altair 4x gas detector msa safety united states. The unit in our tutorial has the standard sensor configuration and detects lel, o2, co and h2s.
Altair 4x multigas detector cross reference factors. Rentals interactive tools webdam asset library safety resource library msa gear product registration. Measuring instruments msa suprema calibration operating manual. Correct accuracy by performing the calibration procedure within this manual. Economical construction saves users more than 50% on calibration gas, replacement sensors and maintenance. What do i need to manually calibrate the altair 4x. This declaration is based on the ectype examination certificate ftzu 07 atex 0169 x in accordance. Altair 4x multigas detectors with msa xcell sensors offer typical cost savings of over 50% on calibration gas, replacement sensors and maintenance. Altair 4x measuring instruments pdf manual download. Use the msa link software to communicate with the instrument. The instrument will perform as designed only if it is used and maintained in accordance with the manufacturers instruction. View and download msa altair 4xr operating manual online. Introducing the altair io360 gas detector available now.
Once the msa altair 4 or msa altair 4x is in normal reading mode, you need to send it into calibration mode. Msa altair 4x how to bump test using the msa galaxy gx2 duration. Safety regulations msa 6 altair 4x gb 1 safety regulations 1. View and download msa altair 2x operating manual online. Provides realtime incident awareness when paired with the msa altair connect app. Altair 4x mining multigas detector in portable gas. Altair 4x msha multigas detector ordering information. Switch on the altair 4x and align the datalink communication port on the altair 4x to the ir interface of the pc. Operating manual altair 5x multi gas detector altair 5x ir multi gas detector order no 1011695100. The altair 4x is an extremely durable multigas detector that simultaneously measures up to four gases from a wide range of xcellr sensor options including combustible gases, o. Altair 2x gas detector is a single or dual gas monitor. Galaxy gx2 automated test system for gas detector calibration. Msa 10107602 altair 4x gas detector, charcoal, lel, o2, co. Minimizes cost of ownership and features the first stand alone bump test.